A passive filter
Passive filter is a filter inductor in series between the rectifier and the capacitor resonator filters,solar panel
or access the mains input side. Its main advantages are: the circuit is
simple, low cost, high reliability, EMI. The main disadvantages are:
the volume weight is large, it is difficult to obtain the input power
factor close to 1 (typically between 0.8 and 0.9 can be achieved),
related to the operating performance and frequency, load changes, and
the input voltage changes, the inductance and capacitance between the
charge, the discharge current is large and so on.
2 Active Power Filter
Active power filter APF (Active P. Wer Filter) is the use of power
electronic inverter and feedback technology, real-time measurement of
the voltage and current waveforms of the nonlinear load, to provide the
required load current harmonics to the electricity grid, Input current
to compensate for the power inverter
grid, so close to a sine wave, reducing the electricity grid input
current THD, and improve the quality of the mains power grid. APE power
generally.
3 Active Power Factor Correction
Rectifier of
Zan and load of indirect PFC converter (both DC / DC converter), the
application of current feedback technology, the end of the input current
iin waveform tracking sinusoidal AC input voltage waveform, iin nearly
sinusoidal. So that the input current THD <5%, while the input power
factor can be increased to 0.99 or higher. This technology applied to
active power devices and feedback technology, so that the input current
waveform is nearly sine wave from the narrow pulses status changes to
improve the input power factor, it is called Active Power Factor
Correction (APFC) active input current waveform shaping technology. The
APFC power generally small, as AC / DC switching power supply, inverter,
AC uninterruptible power supply (UPS), fluorescent lamp electronic
ballasts and other input terminal of the power factor correction.
Its main advantages are: high input power factor, such as 0.97 to 0.99, even close to 1; city power grid tie inverter
input current THD; wide input voltage range ( as 90 ~ 264 V AC) and
broadband; small size, light weight; adjust the input current waveform,
the current negative feedback, the output voltage can be kept
substantially constant. The main disadvantages are: complex circuit,
MTBF decline; costs (such as AC / DC switching power supply plus
top-level APFC, will make the cost of a 15% increase); EMI; efficiency
decreased slightly.